Internal Lining SystemsHoliday TestMinimum Number of CoatsMinimum Thickness (MILS)Average Thickness (MILS)
Unlined–0––
Asphalt Lining 1–113
Cement Lining with Sealcoat 1–1AWWA C104–
Cement Lining without Sealcoat 1–0––
Double Thick Cement Lining with Sealcoat 1–1AWWA C104–
Double Thick Cement Lining without Sealcoat 1  –0––
Protecto 401 Ceramin Epoxy Lining 52500 volts13540
Induron® Red Oxide Epoxy Primer 1–2810
Tnemec® 140 – 1211 Red Oxide Primer 1–2911
Induron® Ruff Stuff 3300 Epoxy 6low volt wet sponge22024

1 NSF approved for drinking water 
2 Primer coat only applied at factory
3 Standard lining and coating for 4″ – 24″ fittings and valves
4 Conforming to AWWA C116
5 Sanitary sewer only
6 12″ and greater, pipe and fittings